STS Decisions in 1998
     
Foreground: 
Background: 
        Click inside the map to zoom in.
        Click near the border to see a neighboring map

Legend

    Table of PPA characteristics in 1998

State  Area Distance   N     Max   Max   Backgr. Priority Delimit   Action    Action Comment
PPA ID sqkm    km    traps  catch before  moths    index   index  recommended taken
IN- 55   12    7.3      3     10     -   0.695      0.18    0.34      -      delimit
IN- 56    4  -13.4      3     23     -   0.957      0.00    0.59      -         -   
IN- 57    1   -3.2      1      7     -   0.930      0.00    0.47      -      delimit
IN- 58    1   -4.6      1     21     -   0.959      0.00    0.45      -      delimit
IN- 60    1   -0.3      1     11     -   0.855      0.00    0.45      -      delimit
IN- 61    1   -5.6      1     12     -   0.928      0.00    0.47      -      delimit
IN- 63   41   42.3      6      3     -   0.179      1.56    0.51      -      delimit
IN- 64    4    9.1      4      4     -   0.533      0.00    0.70      -      delimit
IN- 65    1  -17.6      1     18     -   1.155      0.00    0.39      -      delimit
IN- 67    1   -9.3      1     11     -   1.080      0.00    0.39      -      delimit
IN- 69    1    4.5      1      5     -   0.549      0.00    0.32      -         -   
IN- 72    1   30.6      2      3     -   0.313      1.36    0.58      -      delimit
IN- 73    1   21.0      2      3     -   0.362      1.27    0.53      -      delimit
IN- 74   55    4.1     13      8     -   0.580      0.00    0.92      -         -   
IN- 78   10  -18.8      5     22     -   1.182      0.00    0.63      -      delimit
IN- 79    1  -11.1      1      9     -   0.885      0.00    0.37      -         -   
IN-210   16   -0.2     11      6     -   0.952      0.00    1.14      -      delimit
IN-211   20   13.4     40      4     -   0.525      0.93    3.98      -      delimit
IN-212    9   48.6      2      2     -   0.103      1.35    0.27      -      delimit
IN-213    1    6.5      2      4     -   0.500      0.00    0.68      -      delimit
IN-215    4   45.8      2      2     -   0.094      1.36    0.38      -      delimit
IN-216    1   10.6      2      3     -   0.427      0.20    0.58      -      delimit
IN-217   16   52.9      6      2     -   0.144      1.30    0.62      -      delimit
IN-219   18   51.5      7      2     -   0.223      1.20    0.71      -      delimit
IN-220    8  -15.5      1      7     -   1.180      0.00    0.11      -      delimit
IN-243    1  -11.5      1     10     -   1.045      0.00    0.42      -         -   
IN-245    1  -13.5      1      9     -   1.245      0.00    0.47      -         -   
IN-246    1    5.6      2      4     -   0.524      0.00    0.58      -      delimit
IN-247    1    1.8      1      3     -   0.600      0.00    0.34      -         -   
IN-248    1   -9.9      1      9     -   1.125      0.00    0.32      -         -   
IN-249    1  -15.9      1      9     -   1.064      0.00    0.32      -         -   
IN-250    1    5.1      1      3     -   0.480      0.00    0.32      -         -   
IN-251    1    4.9      1      4     -   0.456      0.00    0.32      -         -   
IN-252    1    1.9      1      3     -   0.525      0.00    0.32      -         -   
IN-279    1   51.1      1      3     -   0.333      1.37    0.32      -      delimit
IN-280   30   36.9     20      4     0   0.354      1.55    1.88      -      delimit
IN-281   13   29.4      4      4     -   0.345      1.54    0.44      -      delimit
IL- 44    1   44.0      1      3     -   0.271      1.44    0.29      -      delimit
IL- 46    2    7.1      2      8     -   0.756      0.00    0.51      -      delimit
IL- 48   13   -3.1     11     15     -   0.879      0.00    1.22      -      delimit
IL- 52    6   -7.5      3     11     -   0.860      0.00    0.55      -      delimit
IL-220    1   30.2      1      4     -   0.244      1.69    0.29      -      delimit

ID = Identification number of the potential problem area (see the map).
Distance =
 
Distance from the beginning of the STS action zone, km. Negative distance means that the PPA is in the monitoring zone.
N traps = Number of traps in the problem area.
Max catch = Maximum number of moths captured within the problem area.
Max before = Maximum number of moths captured in a 3-km neighborhood in the previous year.
Priority index = Shows the priority for STS action (either treatment or delimiting).
Delimit index = Shows how well the area was delimited in the previous year.
Backgr. moths = Mean log moth counts in a 25-km neighborhood.

See details in: Decision algorithm explained.

Home


    For more information, please contact Patrick Tobin or Andy Roberts
    Maintained By Jiang Wu