STS Decisions in 1998
     
Foreground: 
Background: 
        Click inside the map to zoom in.
        Click near the border to see a neighboring map

Legend

    Table of PPA characteristics in 1998

State  Area Distance   N     Max   Max   Backgr. Priority Delimit   Action    Action Comment
PPA ID sqkm    km    traps  catch before  moths    index   index  recommended taken
OH-132    1   59.8      1      3     -   0.587      1.60    0.32      -         -   
OH-136   47   24.4     13     19     -   0.802      2.26    1.03      -      delimit
OH-140    1   99.5      1      3     -   0.187      2.11    0.37      -         -   
OH-141   10   45.9      3      7     -   0.638      2.07    0.38      -         -   
OH-143   99   67.2     13     10     -   0.404      3.03    0.53   delimit   delimit
OH-144    1   88.0      5      3     -   0.267      1.98    1.53      -         -   
OH-145    1  102.4      2      3     -   0.184      2.12    0.76      -         -   
OH-146    1   32.4      1     10     -   0.774      2.17    0.32      -      delimit
OH-148    5   20.5      4     11     -   1.026      1.89    0.58      -      delimit
OH-152    2  101.4     25     18     -   0.121      3.55    5.74    treat    delimit
OH-153    8   40.4      2      3     -   0.411      1.12    0.25      -         -   
OH-154    1   35.3      1      5     -   0.416      1.53    0.42      -      delimit
OH-155   20   83.4      3     10     -   0.167      3.43    0.30   delimit   delimit
OH-156   55   57.3     11      4     -   0.249      1.69    0.78      -         -   
OH-157    1   74.9      3      3     -   0.172      2.34    0.92   delimit      -   
OH-158    1   49.0      1      3     -   0.257      1.42    0.32      -         -   
OH-160   58   56.8      5     19     -   0.099      3.86    0.34   delimit   delimit
OH-161    1   60.1      1      4     -   0.186      1.72    0.29      -         -   
OH-162    1   40.3      2      6     -   0.286      1.99    0.63      -      delimit
OH-164    1   45.1      1      6     -   0.087      2.71    0.29   delimit   delimit
OH-165    1   43.8      1      3     -   0.247      1.32    0.32      -         -   
OH-166    1   30.3      1      3     -   0.238      1.43    0.26      -         -   
OH-167    1   36.4      1      3     -   0.267      1.59    0.29      -         -   
OH-168    1   35.0      1      6     -   0.153      2.30    0.32      -      delimit
OH-170    1   27.1      1      3     -   0.232      1.40    0.37      -         -   
OH-171    8   24.0      4      8     -   0.295      2.26    0.48      -      delimit
OH-172   73   21.0     59      7     -   0.410      2.11    3.23      -         -   
OH-173    1   19.7      1      5     -   0.291      1.76    0.63      -         -   
OH-175   12   19.7      3      8     -   0.293      2.24    0.34      -      delimit
OH-177    4   21.6      3     13     -   0.410      2.67    0.62   delimit      -   
OH-178    3   20.3      4      8     -   0.407      2.19    0.89      -         -   
OH-180    1    8.1      1      3     -   0.485      0.00    1.39      -      delimit
OH-182    1    7.2     14     10     -   0.491      0.43    4.42      -      delimit
OH-183    4    3.1      6     10     -   0.564      0.00    1.11      -         -   
OH-184    7    0.7     13     22     -   0.589      0.00    1.69      -         -   
OH-185   18   -6.5     13     16     -   0.589      0.00    1.32      -         -   
OH-240    1   78.0      1      3     -   0.403      2.06    0.29      -         -   
OH-244    1   30.1      1      3     -   0.486      0.98    0.32      -         -   
OH-246    1   18.8      1      3     -   0.331      1.51    0.82      -         -   
OH-254    1   55.8      1     10     -   0.593      2.64    0.42   delimit   delimit
OH-255    1   55.2      2      7     -   0.593      2.28    0.63      -         -   
OH-256    1   57.3      1     11     -   0.599      2.71    0.34   delimit   delimit
OH-258    1   79.3      1      3     5   0.288      2.98    0.47   delimit      -   

ID = Identification number of the potential problem area (see the map).
Distance =
 
Distance from the beginning of the STS action zone, km. Negative distance means that the PPA is in the monitoring zone.
N traps = Number of traps in the problem area.
Max catch = Maximum number of moths captured within the problem area.
Max before = Maximum number of moths captured in a 3-km neighborhood in the previous year.
Priority index = Shows the priority for STS action (either treatment or delimiting).
Delimit index = Shows how well the area was delimited in the previous year.
Backgr. moths = Mean log moth counts in a 25-km neighborhood.

See details in: Decision algorithm explained.

Home


    For more information, please contact Patrick Tobin or Andy Roberts
    Maintained By Jiang Wu