STS Decisions in 2004
     
Foreground: 
Background: 
        Click inside the map to zoom in.
        Click near the border to see a neighboring map

Legend

    Table of PPA characteristics in 2004

State  Area Distance   N     Max   Max   Backgr. Priority Delimit   Action    Action Comment
PPA ID sqkm    km    traps  catch before  moths    index   index  recommended taken
WI- 62    1   64.0      2      3     1   0.106      2.09    0.63      -      delimit
WI- 71    1   53.5      1      3     1   0.176      1.97    0.45      -      delimit
WI- 91    1   17.5      1      3     3   0.236      2.09    0.42      -      delimit
WI- 92    1    8.8      1      5     4   0.220      1.36    0.45      -      delimit
WI- 93    1   11.3      1      3     4   0.228      1.25    0.39      -         -   
WI- 95    1   12.2      1      5     4   0.246      2.07    0.42      -      delimit
WI-100   10   31.0      4      7     3   0.193      2.92    0.50   delimit   delimit
WI-102    1   18.7      1      5     2   0.478      2.36    0.34   delimit   delimit
WI-103    1   14.0      1      3     2   0.304      1.48    0.39      -         -   
WI-105    1   16.8      1      5     3   0.312      2.24    0.39      -         -   
WI-106    1    5.8      1      6     2   0.472      0.00    0.32      -         -   
WI-117    1   -6.7      1     14    16   0.926      0.00    0.32      -         -   
WI-118  100  -12.4     13    999    18   1.108      1.61    0.52      -         -   
WI-123    1   43.0      2      4     3   0.091      2.67    0.76   delimit   delimit
WI-124    3   40.5      2      4     2   0.124      2.44    0.52   delimit   delimit
WI-125    8   53.3      3      3     2   0.195      2.17    0.39      -      delimit
WI-128    1   46.3      1      3     2   0.236      2.12    0.42      -      delimit
WI-132   20   35.8     15      8     6   0.267      3.55    1.49    treat     treat 
WI-135    1   32.4      1      4     5   0.338      2.58    0.45   delimit   delimit
WI-139   16   17.2      5      4     6   0.292      2.52    0.52   delimit    treat 
WI-140    1   33.5      1      3     4   0.243      2.25    0.39      -      delimit
WI-143   59    5.6     15      9     8   0.308      1.49    1.00      -      delimit
WI-145    4   27.7      2      5     4   0.302      2.78    0.40   delimit   delimit
WI-148    1   27.4      1      3     2   0.271      2.03    0.34      -      delimit
WI-149    1   23.2      1      4     4   0.329      2.47    0.39   delimit   delimit
WI-150    3   10.4      2      4    10   0.450      1.36    0.40      -         -   
WI-151    4   19.2      2      3     5   0.486      1.92    0.36      -      delimit
WI-152   11   16.4      6      5    10   0.410      2.55    0.72   delimit   delimit
WI-153    1   19.9      1      4     4   0.371      2.36    0.39   delimit    treat 
WI-156    1   19.3      1      3     5   0.369      1.96    0.39      -      delimit
WI-157    6   17.8      3      4     1   0.320      1.87    0.46      -      delimit
WI-161    1   12.2      1      5     5   0.319      1.88    0.34      -         -   
WI-162    1   13.4      1      3     3   0.330      1.38    0.32      -         -   
WI-184    1   27.6      1      3     4   0.320      2.13    0.42      -      delimit
WI-185    1   22.6      1      4     4   0.350      2.46    0.32   delimit   delimit
WI-190    1   31.3      2      3     1   0.341      1.83    0.66      -      delimit
WI-255   14   68.2      3      1     1   0.015      1.42    0.32      -      delimit
WI-256    6   84.7      1      1     1   0.019      1.40    0.18      -      delimit
WI-259    6   93.2      1      1     0   0.015      1.16    0.18      -      delimit
WI-303    1  -15.2      1     33    26   1.260      0.00    0.34      -         -   
WI-304    1  -17.2      1     43    14   1.255      0.00    0.34      -         -   
WI-305    1  -13.8      1     52    15   1.548      0.00    0.29      -         -   
WI-306    1  -18.6      1     54    10   1.791      0.00    0.29      -         -   

ID = Identification number of the potential problem area (see the map).
Distance =
 
Distance from the beginning of the STS action zone, km. Negative distance means that the PPA is in the monitoring zone.
N traps = Number of traps in the problem area.
Max catch = Maximum number of moths captured within the problem area.
Max before = Maximum number of moths captured in a 3-km neighborhood in the previous year.
Priority index = Shows the priority for STS action (either treatment or delimiting).
Delimit index = Shows how well the area was delimited in the previous year.
Backgr. moths = Mean log moth counts in a 25-km neighborhood.

See details in: Decision algorithm explained.

Home


    For more information, please contact Patrick Tobin or Andy Roberts
    Maintained By Jiang Wu