State  Area Distance   N     Max   Max   Backgr. Priority Delimit   Action    Action Comment
PPA ID sqkm    km    traps  catch before  moths    index   index  recommended taken
WI-229    1   41.0      1      3     0   0.365      1.33    0.53      -         -   
WI-233    5   40.2      3      4     0   0.413      1.51    0.51      -      delimit
WI-235    4   38.5      2      3     0   0.369      1.31    0.44      -         -   
WI-236   18   33.6      9      7     0   0.394      2.02    0.91      -      delimit
WI-237    3   35.8      2      3     1   0.409      1.51    0.51      -         -   
WI-240    1   39.1      1      3     0   0.297      1.40    0.58      -         -   
WI-243    1   39.4      1      3     0   0.253      1.46    0.53      -         -   
WI-249   34   33.1     13      5     0   0.364      1.74    1.19      -      delimit
WI-250    1   33.6      1      4     1   0.393      1.77    0.55      -         -   
WI-255    6   28.0      3      5     4   0.431      2.38    0.52   delimit   delimit
WI-262    1   34.3      1      3     0   0.256      1.44    0.53      -      delimit
WI-264    1   28.4      2      4     0   0.450      1.32    0.82      -         -       
WI-265    4   23.8      3      5     1   0.480      1.81    0.65      -         -   
WI-266    1   25.6      1      4     0   0.449      1.39    0.53      -         -   
WI-268   62   22.7     24      6     1   0.450      2.03    1.53      -      delimit
WI-269   19   25.3     22      5     4   0.464      2.37    2.21   delimit   delimit
WI-270    3   24.0      2      5     1   0.490      1.84    0.52      -         -   
WI-279    1   28.0      1      3     0   0.328      1.34    0.50      -         -   
WI-282    1   20.9      1      5     1   0.554      1.73    0.45      -      delimit
WI-283    1   19.4      1      8     0   0.579      1.88    0.55      -      delimit
WI-284    7   19.0      3      4     1   0.465      1.46    0.46      -         -   
WI-286   45   22.5     14      7     1   0.409      2.24    1.14      -      delimit
WI-290    9   15.8      4     10     0   0.640      2.01    0.54      -       treat 
WI-293    1   17.1      1      8     1   0.624      2.09    0.53      -         -   
WI-297    1   13.3      1      6     1   0.567      1.31    0.55      -         -   
WI-298    8   14.3      5      5     1   0.484      1.40    0.65      -         -   
WI-301    1   15.3      1      3     3   0.471      1.43    0.58      -         -   
WI-309    1    7.7      1      7     0   0.525      0.00    0.50      -         -   
WI-312    1    6.2      1      8     0   0.515      0.00    0.58      -      delimit
WI-317    4    4.7      5     10    14   0.695      0.99    0.98      -       treat 
WI-322   10    3.3     17      7     3   0.511      0.00    2.14      -       treat 
WI-330    4   -3.5      3     11     2   0.732      0.00    0.67      -         -   
WI-346    1   -1.3      1      4     4   0.857      0.00    0.76      -       treat 
WI-357    1  -11.2      1     51    94   1.084      0.00    0.29      -         -   
WI-360    4  -13.3      2    235    84   1.334      1.26    0.32      -         -   
WI-367    1  -13.8      1     20     3   0.811      0.00    0.32      -         -   
WI-375    1  -12.7      1     75     2   1.360      0.00    0.55      -         -   
WI-382    1   -9.9      1     15    11   0.868      0.00    0.58      -         -   
WI-443    4   37.2      2      2     2   0.506      1.23    0.44      -       treat 
WI-446    6    1.4      2     10     0   0.802      0.00    0.38      -       treat 
WI-447   21   -4.6      7     14     4   0.961      0.00    0.69      -       treat 
WI-448    5   -6.5      7      6     2   0.843      0.00    1.42      -       treat 

ID = Identification number of the potential problem area (see the map).
Distance =
 
Distance from the beginning of the STS action zone, km. Negative distance means that the PPA is in the monitoring zone.
N traps = Number of traps in the problem area.
Max catch = Maximum number of moths captured within the problem area.
Max before = Maximum number of moths captured in a 3-km neighborhood in the previous year.
Priority index = Shows the priority for STS action (either treatment or delimiting).
Delimit index = Shows how well the area was delimited in the previous year.
Backgr. moths = Mean log moth counts in a 25-km neighborhood.

See details in: Decision algorithm explained.

Home


    For more information, please contact Patrick Tobin or Andy Roberts